Chapter 20 · Reading 1 of 3
Writing and reviewing the report
CHFI domains 2, 4
The academy’s draft report on Ferrous Valley runs to 31 pages. The review board has read one sentence closely: “The manual override was set at 02:13:58 UTC.” The PLC recorded 02:13:58 on its own clock, which the examiners measured as 41 seconds fast. The sentence mixed an observation with a conversion that was never applied. A good report structure makes that kind of error hard to write and easy to catch.
The parts of an examination report
Labs use their own templates, but most examination reports contain the same sections, in roughly this order.
- Request and question. Who asked, under what authority, and the question the examination answers.
- Exhibits. Each item with its identifier, description, hash and custody reference.
- Methods and tools. Procedures followed, tool names, versions and settings, and the validation behind them.
- Observations. What was found, each tied to an exhibit and a location within it.
- Interpretation. What the observations mean, how strongly they support it, and the alternatives tested.
- Limitations. What was out of scope, unavailable, unparsed or uncertain.
- Conclusions and signature. Answers to the question, in plain language, signed and dated by the examiner.
Observation, interpretation, alternatives
The most important habit is to separate three kinds of statement. An observation reports what an exhibit contains, and another examiner can reproduce it. An interpretation is the examiner’s reasoned view of what observations mean. An alternative is another explanation that fits the same observations, which the report names and either tests or leaves open.
- Observation
- “Exhibit FV-07, the PLC input log, records the manual-override input changing state at 02:13:58 PLC time. Exhibit FV-08 shows the PLC clock was 41 seconds fast, giving 02:13:17 UTC.”
- Interpretation
- “The bay 4 door was most likely opened using the manual override, about one minute before the door sensor reported it open.”
- Alternatives
- “A fault in the override input could produce the same record. The input showed no other changes for 30 days before or after, and the switch tested normally.”
Interpretations need calibrated language. Phrases such as “consistent with”, “supports” and “strongly supports” should mean the same thing every time the lab uses them, and many labs define them in a glossary at the back of the report. Avoid words that claim certainty the method cannot give, such as “proves” or “definitely”, unless the observation itself is beyond reasonable dispute, like a hash match.
Peer review before signing
Before a report is signed, a second qualified examiner reviews it. A technical review checks that the methods were appropriate, the observations are supported by the exhibits, the interpretations follow and the limitations are stated. An administrative review checks identifiers, hashes, dates, spelling and that every exhibit cited is in the exhibit list. Both are recorded, with the reviewer’s name, the date, the comments and how each was resolved.
| # | Section | Comment | Resolution |
|---|---|---|---|
| 4 | Observations, p. 12 | Override time labeled UTC is the PLC’s local clock value. Recomputed from FV-07 and FV-08: 02:13:17 UTC. | Corrected; both values now shown Closed |
| 5 | Interpretation, p. 14 | “Supervisor operated the override” is not supported by any exhibit placing the supervisor at the switch. | Reworded to “someone at the bay 4 switch” Closed |
| 6 | Limitations | Alibi photo examination not yet complete. | Added as open item Open |
The reviewer found the error by reproducing the decisive observation from the exhibits, not by reading the draft’s summary. That is what the review board asked for, and it is the strongest answer the academy can give.
Writing for the reader
Reports are read by investigators, lawyers, judges and juries, few of whom are examiners. Define each technical term once, put long tables and tool output in appendices, and give every figure a caption that says what it shows. Times should state their zone every time. A good test is whether a reader could follow each conclusion back to the exhibit it rests on.
On the exam, a report separates observations, interpretations and alternatives, ties every observation to an exhibit, states limitations, and is technically and administratively reviewed before signing. The next reading, Authenticating images, audio and video, examines the open item: the alibi photo.
Inspect the three records, then use the evidence to answer the question.
1. Exhibit
FV-12, video of the wallet examination
2. Statement
The device displayed bc1q…k7m4 as receiving address index 7
3. Reproducible?
Yes, by any examiner with the device and PIN
Apply the reading
Why should the report state “the hardware wallet derived address bc1q…k7m4” separately from “the supervisor controlled the marketplace deposits”?
Compare your reasoning
The first is an observation another examiner can reproduce from the device. The second is an interpretation that depends on who used the device, and it has alternatives that the report must name and test. Keeping them apart lets readers see what is proven and what is inferred.